Below is a listing of the special function codes for the R2000D series analyzers. SPECIAL FUNCTION CONTROL CODES • The card supplied with the R-2001D and the applique inside the front-panel cover show the special function codes. The table below lists the special function control codes grouped according to the first digit of the code and then grouped by function type. • A master reset code 0 (zero) causes all function types to revert to the default states listed below. • To obtain a CRT display of all activated special functions, simultaneously depress both keypad cursor keys twice. The screen will automatically return to standard operation after 10 to 15 seconds. CODE MODE ACTIVATES 0 Master Reset Clears all special functions (default state) 10 Encode/Decode Clears all 1x special functions (default state) 11 Encode/Decode Baseband 12 Encode/Decode Decode only 13 Encode/Decode Encode Only 20 Monitor Clears all 2X monitor special functions (default state) 21 Monitor Enables 300 Hz LPFL 22 Monitor Enables 3 kHz LPFL 23 Monitor Enables 20 kHz LPFL 24 Monitor Enables 5 Hz HPFL 25 Monitor Enables 300 Hz HPFL 26 Monitor Enables 3 kHz HPFL 30 Frequency Clears all frequency 3X special functions (default state) 31 Frequency Enables direct frequency readout (10 Hz resolution) 32 Frequency Enables direct frequency readout (1 Hz resolution) 33XY Frequency Enables scan lock from XOO MHz to YOO MHz 3300 Frequency Enables full-band scan lock 34XY Frequency Enables scan latch from XOO MHz to YOO MHz 3400 Frequency Enables full-band scan latch 40 Enables automatic DVM ranging (default state) 41 Enables 1.0 V DVM range 42 Enables 10 V DVM range 43 Enables 100V DVM range 44 Enables 300V DVM range 50 Modulation Meter Enables automatic modulation ranging (default state) 51 Modulation Meter Enables 10 kHz range 52 Modulation Meter Enables 100 kHz range 60 Auto counter resolution (default state) 61 Counter 0.1 Hz resolution 62 Counter 1 Hz resolution 63 Counter 10 Hz resolution 64 Counter 100 Hz resolution 65 Counter 1 kHz resolution 70 Sets factory control states (default state) 71 Sets the current state as the power-on state 72 Initiates a system self test 73 Disables the automatic switching to monitor mode if the input signal is over 0.1W 74 Mutes speaker during GEN 7700 Resets from duplex to simplex (default state) 77XY Sets the last XY in RF memory presets as duplex 78000 Disables audible alarm (default state) 78XYZ Sets deviation audible alarm to XY.Z kHz 79 Resets nonvolatile memory 89 Resets option memory 99 Shows resident version of system software